American Split-phase hybrid inverter (high voltage)

The high-voltage hybrid inverter of the H1 series consists of an inverter and a transformer, both designed for the U.S. market. This split-phase inverter supports a battery voltage range of 85–400 V and offers a power range of 6–12 kW. Accordingly, it is compatible with a wide variety of mainstream batteries and is well-suited for large-capacity residential energy storage systems in North America.

Safe and reliable

It has passed certification tests according to UL 1741:2021, IEEE 1547.1, and UL 1699B standards. The inverter features protection against overvoltage, overcurrent, and overheating.

Flexible configuration

Supports full-power charging and discharging with improved charging/discharging efficiency. Capable of handling 100% unbalanced loads.

Convenient operation and maintenance

Automatically matches mainstream batteries, supports remote software upgrades, and is compatible with two independent battery clusters and battery sharing

Our Benefits

Reduce electricity costs by 50% per year
Free energy available at night
Participate in peak load shifting to gain additional economic benefit
Keeping critical load operation in power of
Support 7*24 remote service

American Split-phase hybrid inverter ESS

Американський інвертор з розділеною фазою ESS (напруга акумулятора >80 В)
Model R6KH1NA R8KH1NA R10KH1NA R12KH1NA
Input (PV)
Max. power(kW) 7.8 10.4 13 15.6
Max. DC voltage(V) 500
MPPT voltage range(V) 125~500
Max.Input current of single MPPT(A) 12
MPPT tracker/strings 4/1
AC output
Rated output power(kVA) 6 8 10 12
Max. apparent Power (kVA) 6.6 8.8 11 12
Max. output current(A) 27.5 36.7 45.8 50
Grid voltage/range(V) 240/211~264
Frequency (Hz) 50 /60
PF 0.8lagging-0.8leading
THDi <3%
AC output topology Split phase、single phase
Battery
Battery voltage range(V) 85~400
Max. charging voltage(V) 400
Full battery voltage(V) 85 110 140 160
Max. charge/discharge current(A) 80/80
Battery type Lithium /Lead-acid
Communication interface CAN,RS485
EPS output
Rated power (kVA) 6 8 10 12
Rated output voltage(V) 220-240 /110-120
Rated frequency(Hz) 50/60
Automatic switching time (ms) <20
THDu <2%
Overload capacity 110%,30S/120%,10S/150%,0.02S
General data
DC Max. efficiency ≥98.2%
CEC efficiency ≥97.2%
Ingress protection IP65/NEMA 3R
Noise emission(dB) <25 <25 <29 <29
Operation temperature(℃) -25~60
Cooling Natural
Relative humidity 0 ~95%(non-condensing)
Operation altitude (m) 2,000 (>2,000 Derating)
Weight(kg) 34
Dimensions W * D * H (mm) 560* 220* 680
Self-consumption(W) <20
Display and communication
Display LCD
Interface:RS485/Wifi/4G/CAN Yes/ Opt/ Opt/ Yes
Safety standard UL1741SA all options, UL1699B, CSA 22.2
EMC FCC Part 15, Class B
On-grid IEEE 1547, Rule 21, Cpuc Rule 21, SRD V2.0 UL1741SA, UL1741SB

DOWNLOAD SPECIFICATIONS AND MANUALS

You can order these and other devices, get a consultation, or start a project development by contacting our specialists right now: