Three phase hybrid inverter

The H3 series three-phase hybrid inverter offers four power levels—8 kW, 10 kW, 12 kW, and 15 kW. It is compatible with both single-phase and three-phase loads and supports 100% unbalanced load. The maximum efficiency can reach up to 97.9%. These three-phase hybrid inverters are designed to enhance energy independence for homeowners.

Safe and reliable

Passed IEC/EN 62109-1/-2, IEC/EN 62477-1, IEC/EN 61000-6-1/-6-3, European grid: EN50549-1, German grid: VDE4105/0124, British grid: G99, South Africa: NRS097-2-1:2017 test certification.

Flexible configuration

Support PV, diesel generator, battery, load at the same time access, also has strong adaptability, support black start. Various working modes can be set flexibly.

Economical and practical

It is more economical to support multiple operating modes. Can be as a UPS for the important loads when power off.

Choose our benefits

Reduce electricity costs by 50% per year
Free energy available at night
Participate in peak load shifting to gain additional economic benefits
Keeping critical load operation in power off
Support 7*24 remote service

Three phase hybrid inverter ESS

Трифазний гібридний інвертор Megarevo ESS
Model R6KH3 R8KH3 R10KH3 R12KH3 R15KH3
DC Input
Max.PV input power (kW) 9 12 15 18 22.5
Max. PV voltage (V) 1,000
MPPT voltage range (V) 180~850
Full power MPPT voltage range (V) 250~850 330~850 430~850 510~850 620~850
Start-up voltage (V) 125
Max. input current per MPPT (A) 13/13
Max. short-circuit current (A) 16/16 16/16 16/16 16/16 25/25
Number of MPPT rackers 2
MPPT number/ Max. input strings number 1/1
Rated input voltage (V) 700
AC Output
Nominal output power to grid (kVA) 6 8 10 12 15
Max. apparent power to grid (kVA) 6.6 8.8 11 13.2 16.5
Max. apparent power from grid (kVA) 13.2 17.6 22 26.4 33
Max. apparent current from grid (A) 19.1 25.5 31.8 38.2 47.6
Nominal output current to grid (A) 8.7 11.5 14.4 17.3 21.7
Max.output current to grid (A) 9.5 12.7 15.9 19.1 23.8
Nominal grid voltage (V) 380/400,3W+N+PE
Nominal grid frequency (Hz) 50/60
THDi <3%
Battery
Max.charging /discharging Power (kW) 6.6 8.8 11 13.2 16.5
Battery voltage range (V) 125~600
Battery working voltage range (V) 150~550
Max.charging /discharging current (A) 50
Rated.charging /discharging current (A) 40
Battery type Lithium and Lead Acid Battery
EPS output
Nominal output power (kVA) 8 8 10 12 15
Max. apparent power (kVA) 8.8 8.8 11 13.2 16.5
Nominal output current (A) 8.7 11.5 14.4 17.3 21.7
Max.output current (A) 9.5 12.7 15.9 19.1 23.8
Nominal output voltage (V) 400 ,3W+N+PE
Nominal output frequency (Hz) 50/60
THDu <2%
Max.efficiency 97.9% 97.9% 98.2% 98.2% 97.6%
Europe efficiency 97.2% 97.2% 97.5% 97.5% 97.8%
MPPT efficiency 99.9%
Max.battery charge/discharge efficiency 97.5% 97.5% 97.5% 97.6% 97.8%
General Data
Ingress protection IP65
Operating temperature range (℃) -25~60
Relative humidity 0~100%
Operating altitude (m) 4,000 (>2,000 Derating)
Dimensions W*H*D (mm) 596*566*220
Weight (kg) 32
Self-consumption(W) <20
Cooling Natural
Noise emission (dB) ≤25
EMC IEC/EN 61000-6-1:2019, IEC/EN 61000-6-2:2019, IEC/EN 61000-6-3:2021,
IEN/EN 61000-6-4:2019, IEC/EN 61000-3-2:2019/A1:2021, EN 61000-3-3:2013/A2:2021,
IEC/EN 61000-3-11:2019, EN 61000-3-12:2011
On-grid Europe:
EN 50549-1:2019/AC:2019, Poland:EN50549-1:2019/Rfg:2016/NC Rfg:2018/PTPiREE:2021,
Germany: VDE-AR-N 4105:2018 /DIN VDE V 0124-100(VDE V 0124-100):2020,
South Africa:
NRS 097-2-1:2017 Edition 2.1, UK:G98/G99/1-6:2022,
Spain:UNE217001:2020 /UNE217002:2020/NTS V2.1:2021-07, IEC61727:2004/IEC62116:2014/IEC61683:1999,
Hungary:EN50549-1:2019/RFG:2016/Hungary, Italy CEI 0-21
Safety standard IEC/EN62109-1:2010, IEC/EN62109-2:201
Display and communication
HMI LCD; APP
BMS CAN
EMS/Meter RS485/RS485
Supported communication interface WIFI / GPRS